Online Peptide Calculator LOGOOnline Peptide Calculator

How It Works

Every number this site produces comes from one short formula. This page shows you that formula, the assumptions behind it, how we round, and what the calculators cannot do.

Last Updated: November 18, 2026


1. The Core Formula

Reconstitution dosing is a two-step conversion: first work out the concentration of the solution you made, then work out what fraction of that solution contains your target dose. Our calculators perform both steps in one expression.

Step 1 — Concentration

A vial holding b mg of peptide, reconstituted with c mL of solvent, gives:

concentration (mcg/mL) = (b × 1000) ÷ c

Multiplying by 1,000 converts milligrams to micrograms, the unit most doses are expressed in.

Step 2 — Volume for Your Dose

For a target dose of d mcg:

volume (mL) = d ÷ concentration = (d × c) ÷ (b × 1000)

Step 3 — Syringe Units

On a U-100 syringe, 1 mL is 100 units, so we multiply the volume by 100. The three steps collapse into the expression our code actually evaluates:

units = (d × c) ÷ (b × 10)

b = peptide in the vial (mg) · c = solvent added (mL) · d = target dose (mcg)

Note what is not in this formula: the syringe size. Syringe choice does not change the volume you need — it only changes how finely that volume is marked on the barrel. It affects our rounding suggestions (section 5), not the underlying number.

2. A Worked Example

A 5 mg vial, reconstituted with 2 mL of bacteriostatic water, with a target dose of 250 mcg:

  • Concentration: (5 × 1000) ÷ 2 = 2,500 mcg/mL

  • Volume: 250 ÷ 2,500 = 0.1 mL

  • Units: 0.1 × 100 = 10 units

Checking against the combined formula:

(250 × 2) ÷ (5 × 10) = 500 ÷ 50 = 10 units

Change the solvent to 1 mL and the same vial yields 5 units for the same 250 mcg dose. The dose is identical; only the volume carrying it has halved. This is the single most common point of confusion in reconstitution, and it is why solvent volume is an input rather than a fixed value.

3. Unit Conversions

ConversionFactorConditions
mg → mcg× 1,000Exact. Definitional.
mL → syringe units× 100Exact, but only on a U-100 syringe. See section 4.
IU → mg÷ (IU per mg)Not definitional. Depends entirely on the substance and the product.

Why IU Is Different

An International Unit is a measure of biological activity, not of mass. There is no universal IU-to-milligram constant, and there cannot be: the ratio is defined separately for each substance by reference to an international standard preparation, and it can differ between manufacturers and between batches of the same substance.

For this reason our IU Calculator treats the conversion factor as an editable input. The presets below are common reference figures offered as a starting point only:

SubstancePreset (IU per mg)
HGH — Human Growth Hormone3
HCG — Human Chorionic Gonadotropin10,000
IGF-1 LR3 — Insulin-like Growth Factor-1 Long Arginine 31,000
Insulin — Recombinant Human Insulin28
Gonadorelin — Gonadorelin1,500
EPO — Erythropoietin120,000

Always check your own product's documentation and override the preset if it differs. A wrong conversion factor produces a wrong result that looks entirely normal. Where both the vial contents and the dose are entered in IU, no conversion is needed and none is applied — the ratio cancels out.

4. Syringe Assumptions

All results assume a U-100 insulin syringe, the international standard of 100 units per millilitre, documented by the U.S. Pharmacopeia and enforced by regulators including the FDA. If your syringe is marked U-40 or U-500, or is a millilitre-only syringe with no unit scale, the unit figures on this site do not apply to it; use the millilitre volume instead.

The three syringes we support differ in how finely they are printed:

SyringeCapacityPrinted graduationsSmallest printed step
0.3 mL30 units30 lines1 unit (0.01 mL)
0.5 mL50 units50 lines1 unit (0.01 mL)
1.0 mL100 units50 lines2 units (0.02 mL)

This is why a smaller syringe is easier to read for a small dose: the same 8 units occupies far more of the barrel on a 0.3 mL syringe than on a 1.0 mL one. The dose itself is unchanged.

5. Rounding and the Water-Volume Suggestion

How We Round

The raw result is computed at full floating-point precision. We round it to two decimal places internally and display one decimal place. Where the displayed figure hides precision, the exact value — to a maximum of three decimal places — is available behind the help icon next to the result. We never round your dose; we only round the presentation of the unit figure derived from it.

The "Pro-Tip" Suggestion

A result like 8.3 units falls between the printed lines on the barrel, which forces you to estimate. Rather than rounding the dose to fix this — which would change how much peptide you draw — our calculators look for a different solvent volume that lands the same dose on a printed line.

The search works as follows:

  • Starting from the volume you entered, we test increasing volumes in 0.1 mL steps, up to a ceiling of 2.0 mL.

  • On a 0.3 mL or 0.5 mL syringe, a result landing on a whole or half unit is accepted; on a 1.0 mL syringe, only a whole unit is accepted, because its lines are printed every 2 units.

  • The first volume that qualifies is offered as a suggestion.

  • If no volume up to 2.0 mL qualifies, we make no suggestion and simply show the original result.

This suggestion changes the concentration of your solution, never the dose. You are free to ignore it; the original figure remains displayed either way. The 2.0 mL ceiling exists because the search would otherwise propose volumes that do not fit common vials.

The Blending Calculator deliberately does not make this suggestion. Each peptide in a blend is reconstituted in its own vial, and silently altering one component's solvent volume would change the step-by-step draw sequence for the whole blend. There, we report the raw figure and leave the solvent volumes to you.

6. Cycle Projection Maths

The Cycle Planner works from a single derived rate:

administrations per day = (times per period) ÷ (period length in days)

From there, the two modes are mirror images:

  • Plan by Duration — total administrations = rate × cycle length in days, rounded to the nearest whole administration; total peptide = dose × total administrations; vials = total peptide ÷ vial contents.

  • Plan by Supply — total administrations = total peptide ÷ dose, rounded down so a partial dose is never counted as available; days = total administrations ÷ rate.

Where a cycle is expressed in months we use 30.4375 days, the mean length of a month in the Gregorian calendar, rather than 30. The vial figure is reported unrounded so you can see the fractional remainder; it assumes no loss to residual volume, priming, or waste, which in practice means you should expect to need slightly more than the figure shown.

7. How We Test Changes

All calculation logic lives in a single shared module, so every calculator on the site evaluates the same expression rather than reimplementing it. Changes to that logic are verified against hand-computed reference cases, including the boundary conditions that tend to break dosing maths: results that land exactly on a graduation, results below one unit, results that exceed the capacity of the selected syringe, and conversion factors entered by hand.

User-visible changes are recorded in the Changelog. This site is built and maintained by one independent developer, not a clinical team — which is precisely why the formula is published here for you to check rather than asked to be taken on trust.

8. Limitations

The arithmetic above is exact. What it rests on is not:

  • We assume the vial contains the mass stated on its label. We cannot verify this.

  • We assume the peptide dissolves completely and distributes evenly. Undissolved material makes the concentration figure wrong.

  • We assume you measure the solvent accurately. An error here propagates directly into every dose drawn from that vial.

  • We assume the displaced volume of the lyophilised powder is negligible. For most peptide quantities it is small, but it is not zero.

  • We ignore degradation over the life of the vial. Potency at week four is not necessarily potency on day one.

  • We have no view on whether the dose you entered is an appropriate one.

A correct calculation on incorrect inputs returns a confidently wrong number, and nothing in the tool can detect that. Please read the full Medical Disclaimer.

If you believe a result is mathematically wrong, email [email protected] with the calculator name, your exact inputs, and the result you saw. Calculation errors are the highest-priority issue we handle.

9. References

The standards our unit definitions rely on: